Samsung SSC-1000 Universal Remote User Manual


 
23
User’s Guide
22
5. Confirmation Matter in Times of
Abnormality Occurrence
Symptom Confirmation and Management Matters
Control of the camera 1. Check the polarity of the RS-485 indication
part is not possible. line.
2. Check if the address of the camera part has
been set up well.
The input channel number Set up the address number of the camera
of the Matrix Switcher part and the input channel number of the
and the number of the Matrix Switcher to be the same.
camera part appear differently.
Because I cannot remember In the state in which the RESET button has
the Password of this been pressed, if you put in again the power,
machine, I cannot enter the machine gets into the state freshly out of
the set-up MENU. the plant, and you can go into the set-up menu.
The contents and the circuits in this explanation can be changed due to
such reasons as the functional improvement of the production.
6. Specifications
ITEM SPECIFICATION
Communication Interface Type RS-485
Port Connector Type Modular Type x2, D-SUB x1
Baud Rate
1200, 2400, 4800, 9600, 19200, 38400 BPS
SAMSUNG, PELCO-D, PELCO-P, VICON
PROTOCOL
PANASONIC, KALATEL, DIAMOND,
AD, PHILIPS,ERNA, VCL TP, TECHWIN
Display LCD 20 4 line
LED MENU, PRESET, PATTERN, SCAN,
AUTO PAN, RESET
Switching Video Switching SEQUENCE, TOUR, SALVO
& Pan/Tilt & Lens Pan left/right
Control Control Tilt up/down
Iris open/close
Focus far/near
Zoom tele/wide
Preset, Auto pan, Scan, Pattern
External AUX1, AUX2, AUX3, AUX4
machinery Control
Power Source DC 9V 600mA
Dimension 315(W)
205(D)
65(H)mm
Weight 1.1kg (Excluding packaged goods)
RS-485 Connector No 3 (Yellow) : DATA “+”,
No 5(Red) : DATA “–”
D-SUB Connector No 2 : DATA “+”, No 3 : DATA “–”
SSC-1000 (gb) 2009.1.8 1:38 PM Page 22