Sanyo DSR-2108 DVR User Manual


 
Recording
17
1
Recording starts automatically when this unit is
turned on.
"C" is displayed on the screen. The connected cameras
are simultaneously recorded.
The recording mode can be changed using
RECORDING under RECORD settings. Settings, such
as image quality, can also be set. (P35)
2
To stop recording, select "RECORDING" under
RECORD settings using the control button ({|) and
select "DISABLE" using the control button (}~).
C” disappears.
A motion sensor can be set for each channel.
1
Adjusting the following settings using the control
button ({|}~).
2
Select "RECORDING" using the control button
({|) and select "MOTION" using the control
button (}~).
3
Select "MOTION ZONE" using the control button
({|) and select the "PARTIAL ZONE" using the
control button (}~), press the ENTER button.
The motion setting screen is displayed.
4
Select the sensor detection position using the
control button ({|}~) and press the ENTER
button.
The frame set for the sensor detection is grainy.
Select a sensor detection position by repeating the
operation.
Once the setting of the event searched is complete,
press the EXIT/STOP button to return to the RECORD
screen.
5
Select "MOTION SENSITIVITY" using the control
button ({|) and select the level of sensitivity
using the control button (}~).
Selections: 1-9 (Low sensitivity)
6
Select "PRE RECORD" using the control button
({|) and select the pre recording as necessary
using the control button (}~).
7
Select "POST EVENT RECORD" using the control
button ({|) and select the recording time as
necessary using the control button (}~).
Selections: 2 - 30 SECONDS, 1 - 5 MINUTES,
10 MINUTES, 15 MINUTES
8
Press the EXIT/STOP button once operations are
complete.
Press the EXIT/STOP button repeatedly to return to the
live video.
B
CONTINUOUS recording
C
MOTION recording
RESOLUTION
CHANNEL
FRAME RATE
•QUALITY
CH1 C
CH3
CH2
CH4
2009/05/03 09:04:54
2%
:A
C
CC
RECORD
RESOLUTION FULL
CHANNEL
FRAME RATE 1 ips
QUALITY NORMAL
RECORDING CONTINUOUS
MOTION ZONE FULL ZONE
MOTION SENSITIVITY 9
ALARM RECORDING -- -- -- --
PRE RECORD OFF
POST EVENT RECORD 5 SECONDS
AUDIO OFF
TIMER SET
REAL-TIME REC SET
11
PARTIAL ZONE FULL ZONE
If "FULL ZONE" is selected, the motion setting screen is
not displayed. Only set the level of sensitivity for MOTION
SENSITIVITY.
RECORD
RESOLUTION FULL
CHANNEL C
FRAME RATE 1 ips
QUALITY NORMAL
RECORDING MOTION
MOTION ZONE PARTIAL ZONE
MOTION SENSITIVITY 9
ALARM RECORDING -- -- -- --
PRE RECORD OFF
POST EVENT RECORD 5 SECONDS
AUDIO OFF
TIMER SET
REAL-TIME REC SET
11
Detection
frame
L8HBT_WA(DSR-2116_2108)(GB).book 17 ページ 2009年5月27日 水曜日 午後4時50分