Sharp 52LE920UN Flat Panel Television User Manual


 
LC-52LE920UN/LC-60LE920UN
Page
23
24
Line Item
1 ERROR STANDBY CAUSE1
2 ERROR STANDBY CAUSE2
3 ERROR STANDBY CAUSE3
4 ERROR STANDBY CAUSE4
5 ERROR STANDBY CAUSE5
6 ERROR STANDBY CAUSE RESET
1 EEP SAVE
2 EEP RECOVER
3 MODEL NAME
4 PANEL SIZE
5 SETTING FOR ADJ
6 PANEL LIMIT
7 PANEL RANGE LIMIT
8 SHORT CHECK MODE
9 SHORT CHECK CURRENT
10 CURRENT SW
Description Remarks (adjustment detail, etc.)
Writing setting values to EEPROM
Reading setting values from EEPROM
"1 Details
of P1.9 (NORMAL STANDBY CAUSE)
2 No operation off
3 No signal off
4 PC power management mode 1
5 PC power management mode 2
6 Off timer
8 Command from RS232C
in the cause of "no operation off"
in the cause of "no signal off"
in the cause of "Standby mode MODEl"
in the cause of "Standby mode MODE2"
in the cause of "SLEEP timer"
in the cause of command by RS-232C
*2 Details
of P1.10 (ERROR STANDBY CAUSE)
11 Prolonged unspecified-signal input in PC mode
17 Temperature error
1A Monitor trouble detected
22 LCD controller Rom error
in the cause of continuous "out of range", PC input mode
in the cause of abnormal temperature
in the cause of abnormal monitor mode
in the cause of software abnormality of LCD controller
6. Special features
* STANDBY CAUSE (Page 1/24)
Display of a cause (code) of the last standby
The cause of the last standby is recorded in EEPROM whenever possible.
Checking this code will be useful in finding a problem when you repair the troubled set.
* EEP SAVE (Page 24/24)
Storage of EEP adjustment value
* EEP RECOVER (Page 24/24)
Retrieval of EEP adjustment value from storage area
5-8