Menu List
A-24 Appendix
Appendix
Items Related to Editing (301~)
The values enclosed in a box are factory settings.
304
Item number Item Function
301 EDIT OPERATION
MODE
film
CG
[normal]
Selects the animation edit mode. For normal editing, use the
“normal” setting.
film: Selects editing in field units for film recording. Since the
standard film speed is 24 frames/sec and VTR frame
rate is 30 frames/sec when the frame frequency is 29.97
Hz or 30 Hz, the duration must be alternated between 2
and 3 fields when recording films. This setting is
automatically activated in film mode. When editing
finishes, the next IN and OUT points are automatically
set.
302 PREROLL TIME 0 sec
.
.
.
[5sec]
.
.
.
30 sec
This sets the preroll time. The range is from 0 to 30
seconds, in steps of 1 second. The preroll time should
generally be set to at least 3 seconds, and for phase
adjustment with an editing controller it is recommended to
set the preroll time to at least 5 seconds.
VAR SPEED RANGE
FOR
SYNCHRONIZATION
[–1to+2]
–1.15 to +2.45
Specifies the variable tape speed range when the variable
speed playback is executed by a remote control unit
connected to the REMOTE1 IN (9P) connector.
–1 to +2: –1 to +2 times normal tape speed
–1.15 to +2.45: –1.15 to +2.45 times normal tape speed
305 EDIT FIELD select [1F]
2F
1F/2F
Selects the start timing for editing when performing tape
editing.
1F: Start editing from field 1 and end on field 2.
2F: Start editing from field 2 and end on field 1.
1F/2F: Following received timing commands.
306 SYNCHRONIZE [accurate]
rough
off
Note
This setting is only active when the frame frequency of
the unit is 29.97 Hz or 30 Hz.
CG: Primarily for recording computer graphics, this setting
allows editing by individual frames. When the edit is
completed, the OUT point automatically becomes the
next IN point. The next OUT point is automatically set
one frame ahead of the IN point.
normal: Use this setting for normal insert editing.
Note
When an editing control unit such as BVE-9100 is
connected for DT editing, select “–1.15 to +2.45”.
Note
When the system frequency of this unit is PsF mode, the
unit always operates with the F1 setting.
Settable range
303 POSTROLL TIME 0 sec
.
.
.
[2sec]
.
.
.
30 sec
This sets the postroll time for which the tape transport
keeps moving after reaching an OUT point.
The range is from 0 to 30 seconds, in steps of 1 second.
When this unit is used as a controller for editing control of
another VTR connected through a 9-pin remote cable, this
selects whether or not to carry out phase synchronization of
the two VTRs, and also the editing accuracy when carrying
out synchronization.
accurate: Editing is carried out with an accuracy of ±0
frames.
rough: Editing is carried out with an accuracy of ±1 frame.
off: Synchronization is not carried out.