Sony FWD- 42PV1 Home Theater Screen User Manual


 
10
FWD-42PV1/42PV1P/42PV1A
(c) Time Control
Clock Set (Hour, Minute)
Syntax Header Category Function Data1 Data2 Data3 Check Sum
Control 0x8C 0x00 0x22 0x03 Hour: 0x00-0x17 Minute: 0x00-0x3B 0xXX
Syntax Header Category Function Data1 Data2 Check Sum
Enquiry 0x83 0x00 0x22 0xFF 0xFF 0xA3
Answer Header Answer Check Sum
Control 0x70 0x00 0x70 Completed
0x70 0x01 0x71 Limit Over
0x70 0x02 0x72 Limit Under
0x70 0x03 0x73 Command Canceled
Answer Header Answer Return to Data Size Return Data1 Return Data2 Check Sum
Enquiry 0x70 0x00 0x03 Hour: 0x00-0x17
*
Minute: 0x00-0x3B 0xXX Completed
* Data of Hour: 0x80 and Minute: 0x00 is set as Return Data when a timer is not set after factory setting.
Clock Set (Week)
Syntax Header Category Function Data1 Data2 Check Sum
Control 0x8C 0x00 0x23 0x02 Week: Code Table(1-e) 0xXX
Syntax Header Category Function Data1 Data2 Check Sum
Enquiry 0x83 0x00 0x23 0xFF 0xFF 0xA4
Answer Header Answer Check Sum
Control 0x70 0x00 0x70 Completed
0x70 0x01 0x71 Limit Over
0x70 0x02 0x72 Limit Under
0x70 0x03 0x73 Command Canceled
Answer Header Answer Return to Data Size Return Data1 Check Sum
Enquiry 0x70 0x00 0x02 Week: FCode Table (1-e) 0xXX Completed