Sony HMZ-T2 VCR User Manual


 
34
HDMI Control
Other Issues
There is no audio input in
Dolby Digital or AAC
format
p The playback equipment may be configured to convert Dolby
Digital or AAC audio output signals to LPCM signals. In this
case, in the playback equipment settings, disable Dolby Digital
or AAC conversion, and then resume playback. For details, refer
to the instruction manual of the equipment used.
Audio playback is not in
the right format
p For dual mono audio, change the “Dual Mono” setting in
“Sound” (page 26). For other audio formats, check the settings of
connected equipment.
Symptom Cause/Action
Connected equipment
cannot be controlled using
the buttons on the head
mounted unit
p Make sure the connected equipment supports the HDMI CEC
functions.
p Make sure “Control for HDMI” setting of the connected
equipment is configured correctly. For details, refer to the
instruction manual of the equipment used.
p The connected AV amplifier (receiver) may not be compatible
with the system’s “Control for HDMI” function. “Control for
HDMI” function will not work correctly in this case.
p Controlling connected equipment by pressing buttons on the
head mounted unit may not be possible immediately after turning
the system on, or immediately after activating “Control for
HDMI” in “General Setup.”
p Make sure the “Control for HDMI” setting in “General Setup” is
set to “On” (page 27).
Symptom Cause/Action
The power indicator keeps
flashing in red
p If the indicator flashes twice every 3 seconds, the head mounted
unit or processor unit may be damaged. Contact your Sony dealer
or local authorized Sony service center.
p If the indicator flashes three times every 3 seconds, the processor
unit has overheated. Wait until the unit cools off and flashing
stops. Make sure not to cover or obstruct the ventilation openings
of the processor unit for proper ventilation.
p If the indicator flashes four times every 3 seconds for a minute,
the head mounted unit has overheated. Wait until the unit cools
off and flashing stops.
p If the indicator flashes five times every 3 seconds for a minute,
both the head mounted unit and processor unit have overheated.
Wait until the units cool off and flashing stops.
Symptom Cause/Action