Sony KV-ES29M90 CRT Television User Manual


 
58
KV-ES29M90
RM-916
2. NTSC RF INPUT
Input signal ; NTSC RF color bar, 75%.
[TWIN] mode, [Service] mode.
(i) SUB CONTRAST
Condition : SAJ 00 PIC 3F
02 COL 0
JGL 01 RGB 4
Adjusting parameter:
LEFT ; YCT 04 SCT
RIGHT ; SYC 04 SCT
VR
VR2
GND
VR1 - VR2 = VR = 1.88 ± 0.07 (Vp-p)
(ii)SUB HUE/SUB COL
Condition : SAJ 02 COL 1F
JGL 01 RGB 7
SAJ 10 HUO 7
Adjusting parameter:
LEFT ; YCT 03 SCL
YCT 00 TNT
RIGHT ; SYC 03 SCL
SYC 00 TNT
VB1 VB2 VB3
VB4
VB1 = VB4 ± 50 mV
VB2 = VB3 ± 50 mV
3. PAL VIDEO INPUT
Input signal ; PAL color bar, 75% to Video 1.
[TWIN] mode, [Service] mode.
(i) SUB CONTRAST
Condition : SAT 00 PIC 3F
SAT 02 COL 0
JGL 01 RGB 4
Adjusting parameter:
LEFT ; YCT 04 SCT
RIGHT ; SYC 04 SCT
VR
VR2
GND
VR1 - VR2 = VR = 1.88 ± 0.07 (Vp-p)
(ii)SUB HUE/SUB COL
Condition : SAJ 02 COL 1F
JGL 01 RGB 7
Adjusting parameter:
LEFT ; YCT 03 SCL
SAJ 10 HUO
RIGHT ; SYC 03 SCL
VB1 VB2 VB3
VB4
VB1 = VB4 ± 50 mV
VB2 = VB3 ± 50 mV