Installation
32 Vidikron Vision Model 65/Model 75 Installation/Operation Manual
Connecting to AC Power Projector: The Vision 65/75 ships
with various types of AC power
cords. Choose the one that is
appropriate to your locale.
Plug the female end of the power
cord into the AC receptacle on the
rear of the projector (AC 100V ~
240V). Then, connect the other end
to your AC power source.
AutoScope Lens Motor: With AutoScope-equipped projectors, an additional power cord is
provided for the lens motor. Plug the female end of the AC power cord into the AC input on
the rear of the lens motor assembly. Connect the other end to a 110
VAC power source.
3.7
Turning on the Power
1. Turn on your source components.
2. If this is an AutoScope-equipped projector, turn on the main power switch at the rear of
the AutoScope lens motor. The lens motor power switch is located next to the AC input
(see above).
3. Turn on the main power switch at the rear of the projector. The POWER LED lights
orange. The LAMP and TEMP LEDs light red briefly, then go out.
4. Press the ON button on the remote control to turn on the Vision 65/75. The POWER LED
flashes green to indicate that it is warming up.
5. When the projector is ready for use, the POWER LED lights solid green.
6. “[Input Name] Source Searching” appears on the screen before the Vision 65/75
identifies the input signal and remains there until a valid signal is detected.
The input voltage to the AutoScope lens motor must be between 100 and
120 VAC. Do not connect the AutoScope lens motor to a 200-240
VAC
power source!
Power
switch
Caution
AutoScope Lens Motor (Rear)
AC Input
Power
Switch
to
110 VAC
Power