Xantech URC-2 Universal Remote User Manual


 
5
Controllers
URC-2
1
2
3
URC-2
TV VCR SAT CBL
DVD TNR CD AUX
POWER
T/V
ENTER
VOL
VOL
CH
CH
PR.CH
MUTE
456
7
89
0
PAUSE
STOP
REW FF
INFOEXIT
SEL
PLAY
MENUGUIDE
ABCD
Status LED
will blink Green
Press and
Release the
SEQ and a
Source Key
simultaneously
to enter the
Sesquence
(Macro) Mode
PGM CANCEL DEL XFER
SEQ DELAY EDIT STEP
Fig. 8
Fig. 9
1
2
3
URC-2
TV VCR SAT CBL
DVD TNR CD AUX
POWER
T/V
ENTER
VOL
VOL
CH
CH
PR.CH
MUTE
456
7
89
0
PAUSE
STOP
REW FF
INFOEXIT
SEL
PLAY
MENUGUIDE
ABCD
Status LED
will go off
Press CANCEL
once, then
Press and
Release the
CANCEL Key
and the active
Source Key
simultaneously
to leave the
Sequence Mode
PGM CANCEL DEL XFER
SEQ DELAY EDIT STEP
b) If you allow more than 30 seconds to elapse between key
presses, the URC-2 will automatically leave the Sequence
Mode (enters Sleep Mode).
If this occurs, simply repeat steps 1 through 3, or go to the EDIT mode.
4. Repeat step 3 for as many IR commands as you want in the
sequence.
5. When finished with a particular key, press the CANCEL key once.
The Status LED will flash Green, indicating that a different Source
or Function key may be selected to enter another sequence
(repeating steps 2, 3 & 4 above).
6. To exit the Sequence Mode completely, press CANCEL once,
then press CANCEL
and the active Source Key simultaneously.
The Status LED will go out. Refer to Fig. 9.
PROGRAMMING DELAYS
Some IR controlled units may require an increased time interval between
certain commands, particularly between a Power ON command and a
Play command, for instance, to operate correctly.
When programming sequences, you can place delays between such
commands so that sufficient time is given for all functions to execute.
The URC-2 allows the insertion of timed delays at any point within a sequence. Proceed as follows:
1. Enter the Sequence Mode and begin your sequences as described previously.
2. Just before you enter a command that requires a delay, press the DELAY key to enter the DELAY
mode. The Status LED will flash Amber.
3. Now press the DELAY key, successively, to enter the number of
seconds of delay you want. (Each press of the DELAY key,
after
the initial press, adds 1 second, up to a maximum of 30 seconds).
NOTE: The URC-2 system already includes a 1/3 second interval
between each command placed in a sequence. Each second you
add will be in addition to the 1/3 second that already exits.
4. Press CANCEL
once
to exit from DELAY mode and return to
Sequence mode.
5. Next, enter the command that requires the delay. Continue
programming the remaining commands you desire in the se-
quence. Just before entering another command requiring a delay,
repeat steps 2, 3 and 4 above.
6. When finished with the sequence, exit Sequence Mode per Fig. 9.
The delay times entered are now stored as part of the sequence.
Sending IR Commands
Once you have “taught” the desired IR commands and/or sequences to
the desired keys, and have exited from the programming modes, you
may send the commands to the controlled equipment simply by pressing
the keys that relate to them. It is recommended that you test each set of commands you have placed in a
bank before proceeding to the next bank.