![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/5/96/5967e40c-9b71-1494-7db8-c0a37d8d3d18/5967e40c-9b71-1494-7db8-c0a37d8d3d18-bg66.png)
Total Access 1248 Octal T1 IMA DSLAM Installation and Maintenance Practice
5-50 61179641L4-5B
Password Control Levels Screen
Password Control Levels
Main Menu\System Management\Password Control\Password Control Levels\
The Password Control Levels screen (see Figure 5-30) is used to manage the usernames and
associated passwords that access the system.
Figure 5-30. Password Control Levels Screen
The password control levels for the default usernames are shown in Table 5-30.
To set or change a username or password, perform the following steps:
1. Navigate to a Username field with the arrow keys.
The Username field displays in reverse video.
2. Press the spacebar to open the field, type a username, and press
ENTER.
3. Press the
TAB key to navigate to the Password field.
The Password field displays in reverse video.
4. Press the spacebar to open the field, type a password, and press
ENTER.
Table 5-30. Password Control Levels for Default Usernames
Username Access Level Control Level
ADMIN System Administrator Read/Write and password control
READWRITE Technician Read/Write
READONLY Read only Read only
TID: TA1248 Total Access 1248
Unacknowledged Alarms: None
Password Control Levels
Username Password Access Level Status
READONLY Read Only Active-Default
READWRITE Technician Active-Default
ADMIN System Administrator Active-Default
Read Only Active
Read Only Inactive
Read Only Inactive
Read Only Inactive
Read Only Inactive
Read Only Inactive
Read Only Inactive
Read Only Inactive
Press space bar to change Status