Introduction
61179641L4-5B 4-3
External Alarms
Alarm Name 25-character string External Alarm Input #
Alarm Severity Critical; Major; Minor; Load shedding Minor
Fan Alarm Delay 0–15 minutes 10 Minutes
Network Port
E1 Provisioning
E1 Framing FAS; FAS+CRC FAS+CRC
E1 Line Code HDB3; AMI HDB3
T1 Provisioning
T1 Type DSX; T1 DSX
T1 Framing ESF; SF ESF
T1 Line Code B8ZS; AMI B8ZS
T1 Line Build Out DSX Type: 0-133 ft; 133-266 ft;
266-399 ft; 399-533 ft; 533-655 ft
T1 Type: 0 dB; –7.5 dB; –15 dB;–22.5
dB
0–133 ft
0 dB
IMA Provisioning
Facility Operation Mode IMA_Group; Unassigned; Pass-through IMA_Group
Group Operation Mode In Service; Out of Service-Maintenance;
Out of Service-Unassigned
Out of Service-Maintenance
IMA Transmit ID 0-255 101
IMA Transmit Frame
Length
32; 64; 128; 256 128
Minimum TX Active Links 1-4 1
Minimum RX Active Links 1-4 1
Maximum Link Diff Delay 0-100 100
Scrambler Enable; Disable Disabled
DSL Menus
ADSL Provisioning
Card Service State In Service; Out of Service-Maintenance;
Out of Service-Unassigned
In Service
Line Service State In Service; Out of Service-Maintenance;
Out of Service-Unassigned
Out of Service-Maintenance
Table 4-1. Default Provisioning Options (Continued)
Provisioning Option Available Options Default Setting