A SERVICE OF

logo

Chapter 4. Front Panel Operation and Menu Structure
4-6
ATLAS
_800
PLUS
User Manual 61200226L1-1
Flow Ctl
This option sets the flow control for the chain port. You can configure
the chain port flow control for
OFF
or
H/W
(hardware).
Type
Sets the Po r t Ty p e to either
Direct
or
Dial
. Select
Direct
to connect to a
local VT 100 and select
Dial
to connect via a modem.
Unit ID
This menu accesses the current Unit ID setting, which is the system
identifier used for ADTRAN Data Link Layer Protocol (ADLP) con-
figuration control (such as using T-Watch PRO).
Editing or changing the Unit ID requires the use of a passcode if a
passcode is defined. See “Set Passcode (Front Panel)” on page 4-8 for
details on working with passcodes. Unit Identification numbers must
be between 2 and 9999. The number 1 is reserved for the PC.
Press
Enter
to record the Unit ID number and establish its availability
when operating by remote control. Press
Cancel
at any time to end
the editing process.
Init Modem
Selecting Init Modem provides the option to send the modem initial-
ization string (e.g., ATE0V1&D2S0=1) from the chain port to a
modem connected to the chain port. Configure this string in the ter-
minal menus. See “Modem Initialization String” on page 5-14 for
details on how to change this field.
The Init Modem option is only used if Type is set to Dial.
S1 through S8 (modules)
Select options S1 through S8 to display the current configuration options of
installed modules. S1 corresponds to slot 1, S2 to slot 2, and so on. When you
select one of these options, you can enable or disable the selected module. The
current status,
ENA
(Enabled) or
DIS
(Disabled), displays next to the module
name. Set this field to
DIS
(Disable) prior to removing a module from the
ATLAS_800
PLUS
unit.
Utility Menu
The Utility menu allows miscellaneous settings to be displayed or modified.
Time/Date
This menu option displays and/or edits the current time and date. The
ATLAS_800
PLUS
maintains the time and date during power off conditions.
After any numeric change, press
Enter
to record the entry and move to the next
editing position. You can also move to a different field to edit by pressing
Enter
at the editing position without making any change, or by using the
up
and
down
arrow
keys
. Press
Cancel
at any time to end the editing process.