One Conair Drive ● Pittsburgh, PA 15202 ● 412-312-6000 ● FAX 412-312-6227 ● www.conairnet.com
MODELS GB920 GB940 GB960
Performance characteristics
Batch size lbs {g} 19.8 {9000} 19.8 {9000} 19.8 {9000}
Maximum throughput lbs/hr {kg/hr}* 5200 {2359} 3300 {1497} 2124 {965}
Bin capacity - main ingredient ft
3
{liter} 8.5 {240.7} 6.7 {189.7} 3.6 {102.9}
Bin capacity - minor ingredient ft
3
{liter} NA 3.6 {107.6} 3.6 {107.6}
Maximum number of materials 6 8 10
Number of discharge valves 2 4 6
Number of additive feeders up to 4 up to 4 up to 4
Control software (# of components) 4 or 12 4 or 12 12
Dimensions inches {mm}
A - Height above mounting plate
†
74 {1880.7} 74 {1880.7} 74 {1880.7}
B - Width
‡
56 {1421.4} 56 {1421.4} 56 {1421.4}
C - Depth
‡
34 {863.6} 34 {863.6} 34 {863.6}
D - Controller height 11.25 {285.75} 11.25 {285.75} 11.25 {285.75}
E - Controller width 12.25 {311.15} 12.25 {311.15} 12.25 {311.15}
F - Controller depth 8.19 {208.03} 8.19 {208.03} 8.19 {208.03}
Weight lbs {kg}
Installed 480 {218} 480 {218} 480 {218}
Shipping 600 {272.2} 600 {272.2} 600 {272.2}
Voltage Running load amps
§
120V/1 phase/60 hz (control and mixer) 8.5 8.5 8.5
220V/1 phase/60 hz (control and mixer) 4.25 4.25 4.25
220V/1 phase/50 hz (control) 0.15 0.15 0.15
220V/3 phase/50 hz (mixer) 2.2 2.2 2.2
400V/3 phase/50 hz (mixer) 1.1 1.1 1.1
Compressed air requirements
Discharge valves 80 psi @ 0.2 ft
3
/min {5.5 bars @ 0.09 liters/sec}; 1/4 in. NPT fitting
Compressed air feeder 40 psi @ 2.0 ft
3
/min {2.8 bars @ 0.94 liters/sec}; 1/4 in. NPT fitting
Maximum loader sizes **
Number of 20 inch loaders 2 2 3
Number of 15 inch loaders 2 4 6
GRAVIMETRIC BATCH BLENDERS
AutoWeigh GB900 Series Models
MOUNTING INTERFACE
SPECIFICATION NOTES:
* Maximum throughput rates are based on 35 lbft
3
pelletized material and using all dispense valves.
Use of feeders for minor ingredients will reduce
this rate. Refer to the selection guide for more
specific throughput information.
†
The optional flow control valve will add 6.5 in. {165
mm} to the total height.We recommend using the
flow control valve when mounting the blender to a
stand, surge bin or hopper.
‡
Feeders will increase depth dimensions. Please
refer to feeder specification.
§
Each auger feeder requires an additional 1 amp @
120V or 0.5 amp @ 240V.
** Maximum loader sizes may be used only when the
loader is adjacent to loaders of a smaller diameter.
SPECIFICATIONS
TPBS013/1199
IBO4
CONTROL
FEEDER LOCATIONS
2
1
D
C
B
A
B
C
GB920
2
1
D
C
B
A
B
C
GB940
A
B
C
GB960
4
3
8
1
7
2
4
3
A
B
C
FRONT VIEW
GB920
SIDE VIEW
GB920/GB940
A
B
C
FRONT VIEW
GB940/GB960
SIDE VIEW
GB960
B
C
D
NOTE: Any one of the
feeders (A,B,C or D)can be
designated position 5 or 6.