Appendix G Barcode Quick Reference Appendix G Barcode Quick Reference
G-3 G-4
P Width of the thin bars (default: / " = 0.35 mm) P Ratio Width to Thin (default: 0 (2 to 1))
4 144
2
Note: The width of bars and gaps should be equal. For this, the parameters P
4
and P should not deviate more than one step.
5
for horizontal Barcode
P hex dec inch mm
4
0 30 48 2/144 0,35
1 31 49 3/144 0,53
2 32 50 4/144 0,70
3 33 51 5/144 0,88
4 34 52 6/144 1,05
5 35 53 7/144 1,23
6 36 54 8/144 1,41
7 37 55 9/144 1,58
for vertical Barcode
P hex dec inch mm
4
0 30 48 2/180 0,28
1 31 49 3/180 0,42
2 32 50 4/180 0,56
3 33 51 5/180 0,70
4 34 52 6/180 0,85
5 35 53 7/180 0,99
6 36 54 8/180 1,12
7 37 55 9/180 1,27
P Width of the thin gaps (default: / " = 0.35 mm)
5 144
2
The values are the same as in P
4
6
P 2 of 5 industrial EAN 13
6
value Codabar UPC-E
Code 39 EAN 8
2 of 5 interleaved UPC-A
Code 93
MSI mod 10/10
Code 128
0 2.0 to 1 SC3
1 2.5 to 1 SC6
2 3.0 to 1 SC9
3 3.5 to 1 SC3
Note: Code 93, MSI 10/10, Code 128 are fixed 2.0 to 1
Best results for Code 39, 2 of 5 industrial, 2 of 5 interleaved, and Codabar
with 2.5 to 1
P Uni-directional or bi-directional printing - standard 0 uni-directional
7
values are: 0 or not programmed means no changes
1 uni-directional printing in LQ
2 bi-directional printing in LQ
3 uni-directional printing in NLQ
4 bi-directional printing in NLQ
Note: A switch from uni-directional to bi-directional printing is only possible if the
parameter UNI-DIRECT.CMD is set to YES via operator panel or
ESC-sequence.
Start Position of Barcode Printing
The start position for barcode printing is the current print position.
For both horizontal and vertical printing, the print position after printing barcodes
is the same line as the start position next to the barcode printed.