Appendix A - Advanced Display Module (ADM)
106 3A2098H
Attempting to dispense from multiple valves simultane-
ously using any other combination will cause an Incom-
patible Valves Settings alarm.
Fluid Plate x, Screen 3 (Delay Settings)
This screen enables users to set on and off delays (in
milliseconds) for each valve and the regulator
.
For an
explanation of the on and off delays, refer to the On/Off
Delays section on page 39.
Fluid Plate x, Screen 4 (Control Loop and Flowmeter
Settings)
This screen enables users to set the meter type (volume
or mass) and the K-Factor for the flowmeter. Users can
also set the Kp, Ki, and Kd for the pressure control loop
as well as Kp and Ki for bead control loop.
NOTE: In systems without a flow meter, the flow meter
settings will be grayed out.
NOTE: It is recommended that these values not be
changed from the factory defaults of 32.00 for Kp,
128.00 for Ki, and 0.00 for Kd.