ELECTRIC FRYERS - SERVICE PROCEDURES AND ADJUSTMENTS
11
HEATING ELEMENT TEST
WARNING:
DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AT THE MAIN CIRCUIT BOX.
THERE MAY BE TWO SEPARATE CIRCUITS. BE SURE BOTH ARE DISCONNECTED. PLACE A TAG ON
THE CIRCUIT BOX INDICATING THE CIRCUIT IS BEING SERVICED.
Perform the appropriate test to obtain the desired information.
NOTE:
Values in the chart are nominal values (± 10%).
3 Phase, 3 Wire Supply Plus Ground
TOTAL
KW
KW / PHASE AMPS PER
LINE 208V
AMPS PER
LINE 240V
AMPS PER
LINE 480V
X-Y X-Z Y-Z X Y Z X Y Z X Y Z
14 4.64.64.6393939343434171717
17 5.65.65.6474747414141202020
21 7 7 7 58 58 58 51 51 51 25 25 25
24 8 8 8 67 67 67 58 58 58 29 29 29
3 Phase, 4 Wire Supply Plus Ground
TOTAL
KW
KW / PHASE AMPS PER
LINE 220/380V
AMPS PER
LINE 240/415V
X-N Y-N Z-N X Y Z X Y Z
14 4.6 4.6 4.6 18 18 18 17 17 17
17 5.6 5.6 5.6 22 22 22 20 20 20
21 7 7 7 28 28 28 25 25 25
24 8 8 8 31 31 31 29 29 29
3 Phase, 3 Wire Supply With Ground 3 Phase, 4 Wire Supply With Ground
TOTAL
KW
RESISTANCE
PER ELEMENT
(OHMS) 208V
RESISTANCE
PER ELEMENT
(OHMS) 240V
RESISTANCE
PER ELEMENT
(OHMS) 480V
RESISTANCE PER
ELEMENT (OHMS)
220/38OV
RESISTANCE PER
ELEMENT (OHMS)
240/415V
1L1
TO
1L1
1L2
TO
1L2
1L3
TO
1L3
1L1
TO
1L1
1L2
TO
1L2
1L3
TO
1L3
1L1
TO
1L1
1L2
TO
1L2
1L3
TO
1L3
1L1
TO
1L1
1L2
TO
1L2
1L3
TO
1L3
1L1
TO
1L1
1L2
TO
1L2
1L3
TO
1L3
14 18.3 18.3 18.3 24.2 24.2 24.2 97.6 97.6 97.6 42.2 42.2 42.2 48.7 48.7 48.7
17 15.2 15.2 15.2 20.4 20.4 20.4 83 83 83 34.6 34.6 34.6 41.5 41.5 41.5
21 12.4 12.4 12.4 16.3 16.3 16.3 66.4 66.4 66.4 27.3 27.3 27.3 33.2 33.2 33.2
24 10.7 10.7 10.7 14.2 14.2 14.2 57.4 57.4 57.4 24.6 24.6 24.6 28.7 28.7 28.7