ELECTRIC FRYERS - REMOVAL AND REPLACEMENT OF PARTS
9
TILT SWITCH
WARNING:
DISCONNECT THE ELECTRICAL
POWER TO THE MACHINE AT THE MAIN
CIRCUIT BOX. THERE MAY BE TWO SEPARATE
CIRCUITS. BE SURE BOTH ARE
DISCONNECTED. PLACE A TAG ON THE
CIRCUIT BOX INDICATING THE CIRCUIT IS
BEING SERVICED.
1. Remove head cover screws.
2. Lift head cover enough to access tilt switch
mounting screws and remove screws.
NOTE:
Do not bend or kink high limit capillary tube.
3. Disconnect tilt switch lead wires.
4. Remove tilt switch.
5. Reverse procedure to install and adjust as
outlined under “ TILT SWITCH
ADJUSTMENT”.
FILTER-READY RETURN
VALVE SWITCH
WARNING:
DISCONNECT THE ELECTRICAL
POWER TO THE MACHINE AT THE MAIN
CIRCUIT BOX. THERE MAY BE TWO SEPARATE
CIRCUITS. BE SURE BOTH ARE
DISCONNECTED. PLACE A TAG ON THE
CIRCUIT BOX INDICATING THE CIRCUIT IS
BEING SERVICED.
1. Open front door.
2. Disconnect lead wires to return valve switch.
3. Remove switch mounting screws.
4. Reverse procedure to install.
Note:
Switch mounting is a fixed location and has
no provision for adjustment. The normally open
contacts close before the valve handle is in the full
open position.