ELECTRIC FRYERS - REMOVAL AND REPLACEMENT OF PARTS
6
HEATING ELEMENTS
WARNING:
DISCONNECT THE ELECTRICAL
POWER TO THE MACHINE AT THE MAIN
CIRCUIT BOX. THERE MAY BE TWO SEPARATE
CIRCUITS. BE SURE BOTH ARE
DISCONNECTED. PLACE A TAG ON THE
CIRCUIT BOX INDICATING THE CIRCUIT IS
BEING SERVICED.
NOTE:
Dont bend or kink high limit capillary tube.
1. Remove the basket hangers or guide block
support ( basket lift models).
2. Lift the elements from the shortening and allow
to drain.
3. Remove the element clamp from the end of the
elements and the clamp at the other end of the
element being replaced..
4. Remove bulb and capillary tube clamps and/or
probe clamps from the element being replaced.
Save for reuse if needed.
NOTE:
Half of each clamp is permanently fixed in
place on the element. Center the Hi-limit bulb in its
clamps before tightening clamp. The Temperature
Probe should be inserted in the grommet in the
head then secured with the clamps.
5. Remove screws from the bottom of the
element head cover.
6. Lower the elements and remove the lift assist
springs from the hooks at the rear of the
machine.
7. Remove four screws securing element bracket.