![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/9/67/96700b41-f576-4395-8057-9d7d5669c370/96700b41-f576-4395-8057-9d7d5669c370-bg8.png)
ELECTRIC FRYERS - REMOVAL AND REPLACEMENT OF PARTS
8
6. Remove the screws that secure the high limit
thermostat.
7. Remove the grommet from the element head.
8. Remove the bulb, capillary tube and the high
limit thermostat from the element head.
9. Reverse procedure to install.
LIFT ASSIST SPRINGS
WARNING:
DISCONNECT THE ELECTRICAL
POWER TO THE MACHINE AT THE MAIN
CIRCUIT BOX. THERE MAY BE TWO SEPARATE
CIRCUITS. BE SURE BOTH ARE
DISCONNECTED. PLACE A TAG ON THE
CIRCUIT BOX INDICATING THE CIRCUIT IS
BEING SERVICED.
1. Remove head cover screws.
2. Remove access cover by prying out on top
edge with small screwdriver.
3. Disconnect spring(s) at bottom.
4. Lift head cover enough to access hanger
mounting bolts.
NOTE:
Do not bend or kink high limit capillary tube.
5. Remove hanger mounting nut and bolt.
6. Remove spacer and washers.
7. Remove hanger and spring out from bottom.
8. To install spring, insert hanger from top with
notch pointing to rear of unit and spring hook
opening pointing to front of unit. Hold in place
while inserting spring from bottom.
9. Hook spring
onto hanger.
Reassemble
spacer and
washers onto
hanger and
secure with bolt
and nut.
10. Reconnect spring at bottom and adjust as
outlined under “LIFT ASSIST SPRING
ADJUSTMENT”.
11. Install covers.