Connecting cable Length = 5, 13, and 19 ft.
armored or vinyl Connector: DE-9P
SENC 150 Mechanical Specications
Mechanical Specications Digital Analog
Resolution 0.5 µm 1 µm 5 µm
Grating pitch 20 µm 20 µm
Scale medium Light transmission reective off of nickel coated glass
Accuracy (@ 20° C) / 1000mm ± 3µm, ± 5µm
Max. cable length 35 ft 70 ft
Reference pulse interval 50mm xed or Position-Trac
TM
Measuring lengths 2” - 120”
Weight w/armor 1.4 + 0.5 lbs/in of measuring length
Force required to move < 0.75 lbs
reading head
Max. slew speed 40 inches/sec
Operating Environment
Temperature 0° to 50° C
Relative Humidity 25% to 95% (non-condensing)
Storage Environment
Temperature - 20° to 70° C
Humidity 20% to 95% (non-condensing)
Protection (IEC 529) IP 53 when installed as per instructions
IP 64 with air Purge
Operating current 220 ma 180ma 75ma
17