Advantech PCM-3780 TV Mount User Manual


 
PCM-3780 User Manual 38
C.6 Counter 0/1 Command Register
1. C2 to C0 : Command Code
000
= Disarm counter
001 = Load counter from LOAD
010 = Disarm and Save counter
100 = Arm counter
101 = Load and Arm counter
110 = Save counter to HOLD
111 = Reset counter
C.7 Counter Command Enable Register
1. CE1 to CE0: Counter Command Enable Bit
0
= Not Select this counter
1 = Select this counter
Base
Address +
HEX
PCM-3780 Register Format
15 14 13 12 11 10 98765432 1 0
6h W Counter 0 Command Register
C2 C1 C0
R Counter 0 Command Register
Eh W Counter 1 Command Register
C2 C1 C0
R Counter 1 Command Register
Base
Address
+ HEX
PCM-3780 Register Format
1514131211109876543 2 1 0
20h W Counter Command Enable Register
CE1 CE0
R Counter Command Enable Register