Approach Tech DVR-3024M, DVR-3024MD DVR User Manual


 
29
RECORD
ALARM / MOTION
CLOCK/ TIMER
COMMUNICATION
DISK
SYSTEM
MAIN MENU
GOTO ALARM/ MOTION PAGE
RECORD
ALARM / MOTION
CLOCK/ TIMER
COMMUNICATION
DISK
SYSTEM
MAIN MENU
GOTO ALARM/ MOTION PAGE
NOTE: The 30 F/S (25 F/S for a PAL unit)
recording rate can only function in a
352x240 (352x288 for a PAL unit) resolution.
REC QUALITY:
This option determines the image quality to
be recorded. The DVR stores images in the
compressed format and allows the image
quality to be altered by the image size.
There are 4 levels of image quality you can
select from: BEST, HIGH, STANDARD, and
BASIC. Selecting the BEST image for use
provides higher-resolution recorded images,
and normally takes up more storage space
than a HIGH, STANDARD or BASIC image
does.
DISK FULL:
This option determines the way to utilize
storage media in case of a full disk.
REWRITE: When the hard-disk is full, the
device continues recording by displacing the
old data.
STOP: When the hard-disk is full, the device
will stop recording.
AUDIO: This option determines the way to
record sound if necessary.
ON: Enables AUDIO recording.
OFF: Disables AUDIO recording.
4.2 ALARM / MOTION Setting
This menu allows users to program the
configuration of alarm recording only when an
alarm input is activated. The device will
record as long as the alarm input is activated.
ALM OPERATION:
This option determines whether to
activate/deactivate the alarm recording when
it detects an alarm input.
ON: The device activates the alarm recording
when it detects an alarm input.
OFF: The device ignores the alarm signal
when it detects an alarm input.
AUDIO:
This option determines the way to record
sound if necessary.
OFF: Disables AUDIO recording.
ON: Enables AUDIO recording.
ALM TYPE:
This option allows users to set a type of alarm
input corresponding to the sensor signal in
use.
NO: Normally Open. This is to be used with
the type of alarm sensor whose contact
remains open in normal conditions and
ALARM/MOTION
ALM OPERATION : OFF
AUDIO : OFF
ALM TYPE : NO
ALM DURATION : 30 SEC
PRE-ALARM : OFF
MOTION SETTING
MAIN PAGE
ALARM RECORD ENABLE