ATEN Technology VS1814T TV Cables User Manual


 
Chapter 4. RS-232 Commands
17
Baud Rate Setting Commands
You can set up the VS1814T / VS1818T baud rate via RS-232. The formula for
Baud Rate setting commands is as follows:
Baud + Baud Rate Setting value [Enter]
For example, to set the baud rate to 9600, input the following:
baud 9600 [Enter]
The following tables show the possible values for the Control string
:
The following table shows the available command list:
Command Description
baud Power On Detection command
Control Description
9600 Uses 9600 baud rate
19200 Uses 19200 baud rate (default)
38400 Uses 38400 baud rate
57600 Uses 57600 baud rate
Command Control Enter Description
baud 9600 [Enter] The VS1814T / VS1818T implements 9600
baud rate setting
baud 19200 [Enter] The VS1814T / VS1818T implements 19200
baud rate setting (default)
baud 38400 [Enter] The VS1814T / VS1818T implements 38400
baud rate setting
baud 57600 [Enter] The VS1814T / VS1818T implements 57600
baud rate setting