Dell R610 Home Theater Server User Manual


 
42 About Your System
Embedded NIC
x
and
NIC
y
:
OS NIC=DISABLED,
Management
Shared NIC=
DISABLED
The OS NIC interface is
disabled in BIOS. The
Management Shared NIC
interface is disabled in
management tools.
Check the system
management software or the
System Setup program for
NIC settings. If a problem is
indicated, see
"Troubleshooting a NIC."
Embedded NIC
x
and
NIC
y
:
OS NIC=DISABLED,
Management
Shared NIC=
ENABLED
The OS NIC interface is
disabled in BIOS. The
Management Shared NIC
interface is enabled in
management tools.
Check the system
management software or the
System Setup program for
NIC settings. If a problem is
indicated, see
"Troubleshooting a NIC."
Error 8602 -
Auxiliary Device
Failure. Verify
that mouse and
keyboard are
securely
attached to
correct
connectors.
Mouse or keyboard cable is
loose or improperly
connected.
Reseat the mouse or
keyboard cable.
Defective mouse or keyboard. Ensure that the mouse or
keyboard is operational. See
"Troubleshooting a USB
Device."
Gate A20 failure Faulty keyboard controller;
faulty system board.
See "Getting Help."
General failure The operating system is
unable to carry out the
command.
This message is usually
followed by specific
information. Note the
information, and take the
appropriate action to resolve
the problem.
Invalid
configuration
information -
please run SETUP
program.
An invalid system
configuration caused a
system halt.
Run the System Setup
program and review the
current settings. See "Using
the System Setup Program
and UEFI Boot Manager."
Table 1-2. System Messages (continued)
Message Causes Corrective Actions