50 About Your System
Timer chip
counter 2 failed
Faulty system board. See "Getting Help."
TPM
configuration
operation
honored. System
will now reset.
A TPM configuration
command has been entered.
The system will reboot and
execute the command.
Information only.
TPM
configuration
operation is
pending. Press
(I) to Ignore OR
(M) to Modify to
allow this change
and reset the
system.
WARNING:
Modifying could
prevent
security.
This message displays during
system restart after a TPM
configuration command has
been entered. User
interaction is required to
proceed.
Enter I or M to proceed.
TPM failure A Trusted Platform Module
(TPM) function has failed.
See "Getting Help."
Unable to launch
System Services
image. System
halted!
System halted after <F10>
keystroke because System
Services image is either
corrupted in the system
firmware, or the system
firmware has been lost due to
system board replacement.
Restart the system and
update the Unified Server
Configurator respository to
the latest software to restore
full functionality. See the
Unified Server Configuration
user documentation or more
information.
Table 1-2. System Messages (continued)
Message Causes Corrective Actions