Echo BRD-280 Universal Remote User Manual


 
20
a I r f I l t e r
Level 1.
Parts required: REPOWER
TM
AIR & FUEL FILTER KIT.
1. Close choke (Cold Start Position [
]). This prevents dirt from
entering the carburetor throat when the air lter is removed. Brush
accumulated dirt from air cleaner area.
2. Remove air lter cover. Brush dirt from inside cover.
3. Remove air lter and lightly brush debris from lter. Replace lter
if it is damaged, fuel soaked, very dirty, or the rubber sealing edges
are deformed.
4. If lter can be reused, be certain it:
• Fits tightly in the air lter cavity.
• Is installed with the original side out.
5. Install air lter cover.
f u e l f I l t e r
Level 1.
Parts required: REPOWER
TM
AIR & FUEL FILTER KIT.
DangEr
Fuel is VERY ammable. Use extreme care when mixing, storing
or handling.
1. Use a clean rag to remove loose dirt from around fuel cap and
empty fuel tank.
2. Use the “fuel line hook” to pull the fuel line and lter from the
tank.
3. Remove the lter from the line and install the new lter.