Eiki LC-X71 LC-X71L Projection Television User Manual


 
The LAMP REPLACE indicator will light when the total
lamp used time (corresponding value) reaches 2,500
hours. This is to indicate that lamp replacement is
required. The total lamp used time is calculated by
using the below expression;
Total lamp used time = Teco + Tnormal x (1.666)
Teco: used time in Eco mode
Tnormal: used time in Normal and Auto mode
You can check the lamp counter following procedure.
1 Press and hold the POWER ON-OFF button on the
projector or the remote control unit for more than 20
seconds.
2 The projector used time and lamp used time will be
displayed on the screen briefly.
You can also check "Lamp Counter" in "Setting Menu".
This value is actual lamp used time.
"Lamp Time" = Teco + Tnormal
Counter
Projector 475H
Lamp
Normal 100H
Eco 375H
Corresponding value
542H
- 19 -
WARNING:
- For continued safety, replace with a lamp assembly of the same type.
- Allow the projector to cool for at least 45 minutes before you open the
lamp cover. The inside of the projector can become very hot.
- Do not drop the lamp module or touch the glass bulb! The glass can
shatter and cause injury.
Procedure
1 Tu rn off the projector and disconnect the AC cord. Allow the projector to
cool for at least 45 minutes.
2 Loosen 2 screws with a screwdriver and open the lamp cover.
3 Loosen 2 screws and pull out the lamp assembly by grasping the handle.
4 Replace the lamp assembly securely and tighten 2 screws.
5 Close the lamp cover and tighten 2 screws.
6 Connect the AC cord to the projector and turn on.
Note:
- Do not reset the Lamp Replace Counter, except after lamp is replaced.
- The projector can not be turned-on with lamp cover removed, because
when the lamp cover is removed, the interlock switch is also released to
switch off the mains power for safety.
7 Reset the Lamp Replace Counter, see below explanation.
Lamp Replacement
Recommendation
Should the air filter become clogged
with dust particles, it will reduce the
cooling fan’s effectiveness and may
result in internal heat build up and
short lamp life. We recommend clean-
ing the air filter after the projection
lamp is replaced.
Refer to “Air Filter Cleaning”.
Lamp cover
ORDER REPLACEMENT LAMP
T
ype No.
Service Parts No.
POA-LMP101 610 328 7362
Screws
Handle
Lamp Assembly
1 Tu rn the projector on, and press the MENU button to display the On-
Screen Menu. Press the POINT LEFT/RIGHT buttons to move a red
frame pointer to SETTING menu icon.
2 Press the POINT DOWN button to move the red frame pointer to “Lamp
counter” and then press the SELECT button. The next box appears.
3 Press the POINT UP/DOWN buttons to select Reset and then press the
SELECT button. The "Lamp replacement counter reset?" appears. Move
the pointer to [Yes] and the press the SELECT button.
4 Another confirmation dialog box appears and select [Yes] to reset Lamp
Replace Counter .
How to reset Lamp Replace Counter
Please refer to the owners manual for further information.
How to check lamp used time
Total lamp used time (corresponding value)
Setting Menu
Lamp Counter Display
Projector used time
Total lamp used time (actual)