Eiki LC-X71 LC-X71L Projection Television User Manual


 
- 47 -
Chassis Description
LED indication and projector condition
• • • on
• • • flashing
• • • dim
• • • off
*When the projection lamp reaches its end of life, the LAMP REPLACE indicator lights yellow. When this indicator
lights yellow, replace the projection lamp with a new one promptly. Reset the Lamp replacement counter after
replacing the lamp.
The projector is in cooling mode. It cannot be turned on until
the READY indicator lights green.
The projector detects an abnormal condition and cannot be
turned on. Unplug the AC power cord and plug it again to turn
on the projector. If the projector is turned off again, disconnect
the AC power cord and contact the dealer or the service
center for service and checkup. Do not leave the projector on.
It may cause electric shock or a fire hazard.
The projector is in the Power management mode.
The temperature inside the projector is abnormally high.
The lamp cannot light up. (The projector is preparing for stand-
by or the projection lamp is in cooling mode. The projector
cannot be turned on until the cooling process is completed.)
The lamp cannot light up. (The lamp has been cooled down
enough and the projector is in stand-by mode and ready to be
turned on with the POWER ON-OFF button.)
The projection lamp reaches its end of life.
Replace the lamp and then reset the Lamp replacement
counter. The indicator is turned off.
The projector is OFF. (The AC power cord is unplugged.)
The projector is ready to be turned on with the POWER ON-
OFF button.
The Warning Temp. indicator blinks red to let you know the
internal temperature of the projector exceeds a normal level. If
the temperature goes up further, the projector will be turned
off automatically and the Ready indicator goes out. When the
projector is cooled down enough and the temperature returns
to normal, the READY indicator lights green and the projector
can be turned on again. (The WARNING TEMP. indicator
keeps blinking.) Check and clean the air filters.
Projector Condition
The projector is operating normally.
The projector is cooled down enough and the temperature
returns to normal. When turning on the projector, the
WARNING TEMP. indicator stops blinking. Check and clean
the air filters.
LAMP
REPLACE
yellow
Indicators
READY
green
LAMP
red
WARNING
TEMP.
red
Check the indicators for projector condition.