Eiki LC-X71 LC-X71L Projection Television User Manual


 
- 51 -
Chassis Description
Error history log
Group No. Item No. Data (Error Code) <-- See table below
91 0 <-- The Latest Error
1
2
3
::
::
::
48
49
Normal 0 -
1000 PJNET, S5V
1001 AV, -5V
1002 AV, S5V
1003 MAIN, S-5V
1004 M/A, 12V
1005 FAN, 16V
1006 SWFPGA, 1.2V
1007 SWFPGA, 2.5V
1008 ANALOG, 1.8V
Power Failure 1009 FPGA, 1.5V
1010 GAMMA, 15.5V
1011 MAIN, 6V
1012 MAIN, 3.3V
1013 ANALOG, 3.3V
1014 ANALOG, 5V
1015 GAMMA, 1.8V
1016 LAMP FAN, 16V
1017 Factory use
1018 Factory use
1019 Factory use
2000 Sensor A detects abnormal temperature.
2001 Sensor A fails measurement.
2100 Sensor B detects abnormal temperature.
2101 Sensor B fails measurement.
Temperature Error 2102 Sensor B-A temperature error
2200 Sensor C detects abnormal temperature.
2201 Sensor C fails measurement.
2202 Sensor C-A temperature error
3000 Lamp fails on.
Lamp Error 3001 lamp goes out.
3002 Communication error on lamp
Error Error Code Error Information
The projector provides the error history log function. To check the logs, you need to enter the service mode and select
Group No. "91" and Item No. "0" to "49". The error code is displayed on the Data column. The description of the error
code is listed on the table below.
How to enter the service mode and selection of the group and item, see "Service Adjustment Menu Operation" on
page 24.