Furuno AD-100 TV Converter Box User Manual


 
3-8
2) Default setting
This unit is set at the factory for connection with the gyrocompass specifications tabulated below.
1) Type : AC synchro
2) Frequency : 50/60Hz
3) Rotor Voltage : Between 60VAC and 135VAC
4) Stator Voltage : Between 60VAC and 135VAC
5) Gear Ratio : 360X
6) Supplied Power : Between 30VAC and 135VAC
3) Setting procedure
(1) Type of gyrocompass
Type SW1-4 SW1-5 SW1-6 JP1
AC Synchro
DC Synchro
DC step-by-step
Full wave pulsating current
Half wave pulsating current
OFF OFF OFF #1, #2, #3
OFF OFF OFF #2, #3, #4
ON OFF OFF #4, #5, #6
OFF ON OFF #4, #5, #6
ON ON OFF #4, #5, #6
(2) Frequency
Frequency SW1-7 SW1-8
50/60Hz
400Hz
500Hz
DC
OFF OFF
ON OFF
OFF ON
ON ON
(3) Rotor voltage
This is for AC synchro type gyrocompass only. For the rotor voltage of the DC synchro type
will be at step 6.
Rotor Voltage SW2-1 JP3
20 to 45VAC
30 to 70VAC
40 to 90VAC
60 to 135VAC
ON #2
OFF #2
ON #1
OFF #1
(4) Stator voltage
Stator Voltage SW2-2 SW2-3 JP2
20 to 45VAC
30 to 70VAC
40 to 90VAC
60 to 135VAC
20 to 60VDC
40 to 100VDC
ON OFF #2
OFF OFF #2
ON OFF #1
OFF OFF #1
ON OFF #2
OFF OFF #2
-
Continued -