Furuno AD-100 TV Converter Box User Manual


 
3-10
Segment Function Setting
SW1-7, -8 Frequency
50/60Hz
400Hz
500Hz
DC
SW1-7 SW1-8
OFF OFF
ON OFF
OFF ON
ON ON
(2)
DIP Switch SW2, SW3
Segment Function Setting
SW2-1 Rotor Voltage
20 to 90VAC
30 to 135VAC
SW2-1
ON
OFF
SW2-2,
SW2-3
Stator Voltage
20 to 90VAC or 20 to 60VAC
30 to 135VAC or 40 to 100VDC
SW2-2 SW2-3
ON OFF
OFF OFF
SW2-4 Selftest SW2-4
ON Continuous
OFF One cycle
SW2-5
SW2-6
Output interval of the output data SW2-5 SW2-6
OFF OFF 1s
ON OFF 200ms
OFF ON 100ms
ON ON 25ms
SW2-7 Stator signal breaking detection SW2-7 ON Disable
OFF Enable
SW2-8 Reset CPU Normally off
Turn ON and OFF to reset CPU
SW3-1 Selection of the output data
SW3-1 ON IEC61162-1 or
NMEA0183 Ver 2.0/3.0
OFF NMEA0183 Ver 1.5
SW3-2 Baud rate of the output data SW3-2 ON 38,400bps
OFF 4,800bps
SW3-3 Power fail detection SW3-3 OFF Disable
ON Enable
SW3-4 Not used
Jumper JP1
Segment Function Setting
#1, #2, #3 Type of Gyrocompass
AC Synchro
DC Synchro
DC Step
Full Wave Pulsating Current
Half Wave Pulsating Current
#1, #2, #3
#2, #3, #4
#4, #5, #6
#4, #5, #6
#4, #5, #6