Heath Zenith 598-1116-10 Universal Remote User Manual


 
10 598-1116-10
Junction box ground wire to green

Wiring Floodlight


White to
White
 to

Gasket
Mounting
Strap
Mounting
Bolt
Rubber
Plug
FLOODLIGHT
Features and Ratings:
• Up to 150 Watt maximum
incandescent load or 240 Watt
maximum halogen load (up to
75 Watt maximum incandescent,
or 120 Watt maximum halogen, per lampholder).
• Minimal wiring required.


1. Remove the existing light xture.
2. Install the mounting strap as shown using two screws that t
your junction box.
Note: The plastic hanger can be used to hold the xture while
wiring. Thread the small end of the plastic hanger through the
hole in the center of the cover plate. Insert the small end into
one of the slots on the mounting strap.
3. Route the wires from the light receiver through the large gasket
holes.
4. Twist the junction box wires and xture wires together as shown.
Secure with UL approved wire connectors.
5. Align the cover plate and cover plate gasket. Secure with
mounting bolt.
6. Push the rubber plug rmly into place.
7. Not intended for waterproof junction boxes. Fixture should be
surface mount only. Caulk the wall plate mounting surface with
silicone weather sealant.
8. Adjust the lamp holders by loosening the lock nuts. Note: Do
not rotate the lamp holders more than 180° from the factory
setting.
CAUTION: To avoid water damage and electrical shock,
keep lamp holders 30° below horizontal.
9. Screw incandescent bulb up to rated wattage into module.
When screwing in the lamps, do not overtighten.
CAUTION: Do not exceed the maximum load limits listed
above.
10. Check operation. Activate transmitter being used with receiver
(see transmitter instructions). A signal will be sent to the receiver
to turn the receiver ON or OFF.