Honeywell DC300K-E Universal Remote User Manual


 
51-52-03-07
Page 5
Specifications
Design
CE Conformity (Europe)
This product is in conformity with the protection requirements of the following
European Council Directives: 73/23/EEC, the Low Voltage Directive, and
89/336/EEC, the EMC Directive. Conformity of this product with any other “CE
Mark” Directive(s) shall not be assumed.
Product Classification:
Class I: Permanently Connected, Panel Mounted Industrial Control Equipment
with protective earthing (grounding). (EN61010-1)
Enclosure Rating:
Panel Mounted Equipment, IP 00, this controller must be panel mounted.
Terminals must be enclosed within the panel. Front panel IP 65 (IEC 529).
Installation Category
(Overvoltage Category):
Category II: Energy-consuming equipment supplied from the fixed installation.
Local level appliances, and Industrial Control Equipment. (EN 61010-1)
Pollution Degree:
Pollution Degree 2: Normally non-conductive pollution with occasional
conductivity caused by condensation. (Ref. IEC 664-1)
EMC Classification:
Group 1, Class A, ISM Equipment (EN 55011, emissions), Industrial Equipment
(EN 50082-2, immunity)
Method of EMC Assessment:
Technical File (TF)
Declaration of Conformity:
51309303-000.
Accuracy
± 0.20% of span typical (± 1 digit for display)
15 bit resolution typical
Temperature Stability
± 0.01% of Full Scale / ˚C change
Input Signal Failure Protection
Thermocouple Inputs:
Upscale or downscale burnout
Burnout Current:
0.13 microamps
Failsafe Output Level:
Configurable 0-100%
Input Impedance
4-20 Milliampere Input:
250 Ohms
0-10 Volt Input:
200K Ohms
All Other:
10 Megohms
Stray Rejection
Common Mode
AC (50 or 60 Hz): 120 dB (with maximum source impedance of 100 Ohms) or ± 1
LSB ((least significant bit) whichever is greater.
Normal Mode
AC (50 or 60 Hz): 60 dB (with 100% span peak-to-peak maximum)
Alarm Output One SPDT electromechanical relay.
A second alarm is available using the second control relay. This is not available
with Relay Duplex, Position Proportional, or Three Position Step control.
Up to four setpoints are independently set as high or low alarm, two for each
relay. Setpoint can be on either Input, Process Variable, Deviation,
Communication Shed, or Output. A single adjustable hysteresis of 0.0 to 100.0%
is provided. The controller can also be set to alarm on shed from
communications. The alarm can also be set as an on or off event at the
beginning of a setpoint ramp/soak segment.
Alarm Relay Contacts Rating
Resistive Load:
5 ampere at 120 Vac or 30 Vdc, 2.5A at 240 Vac.