ICP DAS USA 7000 TV Converter Box User Manual


 
7000 Bus Converter User Manual (version 1.2,Feb/2003, 7PH-006-10) --------------- 68
5.3 I-7510AR:
5.3.1 Pin Assignment and Specifications:
Specifications
Input: RS-485/RS-422
Output: RS-485/RS-422
Speed: “Self Tuner” inside, auto switching
baud rate, from 300 to 115200 BPS
Isolation voltage: Three-way 3000Vdc
Connector: plug-in screw terminal block
Power requirements: +10V to +30VDC
Power consumption: 2.2W(Max)
I-7510AR
RS-422/485 Repeter
( RS-485 )
( RS-485 ) ( RS-422 )
( RS-422 )
Variable Baud Rate
300,..9600,..115.2K
Variable Rate Format
Introduction
I-7510AR is exactly the same as I-7510A except
for the isolation site, The isolation site of I-7510A
is located in the input interface circuit, but the
isolation site of the I-7510AR is located in the
input and output interface circuit. In other words,
I-7510AR is three- way isolation repeater
module.