JVC LM-170 Flat Panel Television User Manual


 
17
ENGLISH
How to Use the External Control
7 About the external control
The monitor has the MAKE/TRIGGER terminal, which allows you to control the monitor by the MAKE (make contact)
or TRIG. (trigger) system.
MAKE (make contact) system: Controls the function by short-circuiting the corresponding pin terminal to the
GND pin terminal, or disconnecting (opening) it.
TRIG. (trigger) system: Controls the function by inputting the pulse signal instantaneously to the
corresponding pin terminal.
* Select “MAKE” or “TRIG.” from “REMOTE SYSTEM” in the SET-UP MENU.
“REMOTE SYSTEM” on page 16
NOTE:
• When using the make contact system, you cannot use the buttons on the front panel or menu to utilize functions which are
controlled through the MAKE/TRIGGER terminal. (When using the trigger system, you can also use those functions using the
buttons on the front panel or the menu.)
7 How to use the MAKE/TRIGGER terminal
No. Functions to be controlled Opening Short-circuiting
*1
1
Changes the input to VIDEO 1 Invalid Valid
2
Changes the input to VIDEO 2 Invalid Valid
3
Changes the input to DVI Invalid Valid
4
Changes the input to RGB Invalid Valid
5
——
6
Changes ASPECT to 16:9 Off On
7
External control Invalid Valid *2
8
GND ——
*1 The TRIG. (trigger) system switches each function by short-circuiting for approx. 1 second.
*2 External control (the 7th pin terminal) is controlled by the MAKE (make contact) system even when you select
the “TRIG.” (trigger) system.
Operation
1. Short-circuit the 7th pin terminal (External control) to the 8th pin terminal (GND) so that the monitor can be
controlled externally.
2. When selecting the “MAKE” (make contact) system, operate each function by short-circuiting the
corresponding pin terminal to the 8th pin terminal (GND) or opening it.
When selecting the “TRIG.” (trigger) system, operate each function by pulse control, that is short-circuiting the
corresponding pin terminal to the 8th pin terminal (GND) for about 1 second.
NOTE:
• When controlling No. 1 to 4 pin terminals by the MAKE (make contact) system, only one terminal must be short-circuited. (Other
terminals must be opened.)
• When selecting the “TRIG.” (trigger) system, you can operate only one function at a time. Operate the functions one by one.
This is a female
terminal.
03_LM170&150-EN4.indd 1703_LM170&150-EN4.indd 17 06.7.21 0:39:21 PM06.7.21 0:39:21 PM