Maintenance Port Parser Commands
54-0166
85
E.4 Tracking and Conical
Scan Commands
Target Location
Function: reports the target location in antenna frame; data
format is E### for elevation in degrees 000-900 and
A#### for azimuth in degrees 0000-3599 with
implied decimals
Command: TGTLOCATION
Response: Target Location = A = E###, A####
B = E###, A####
Analog Signal Strength Report
Function: reports signal strength from RF detector circuit in
A/D counts (000-FFF Hex)
Command: SIGLEVEL
Response: Signal Strength = XXXX
E.5 RF Board Commands
Serial Communications, Status/Polarization Report, Tone Changes
Function: starts serial communications, reports status and
polarization/tone changes
Command: @S
Response: S,s,p,b,m <cr> every 5 seconds until ><cr>is
returned from system software
Where: s = satellite (A = primary, B = secondary)
p = polarization (V = vertical, H = horizontal,
R = right, L = left, X = no LNB power)
b = band (H = high band, L = low band,
G = Latin America, U = USA)
m = mode (V = valid, I = invalid)*
* The Mode bit is used to evaluate the Satellite, Polarization and Band
combination vs. the Frequency/Symbol Rate/FEC currently in RAM. This
bit will be set to invalid if the Frequency for the selected combination is
set to 0x0000; otherwise it will be set to valid. For example the Mode bit
will be set to invalid when the frequency is set to 00000 to indicate that
there is not a frequency to track for the LNB tone and voltage setting.
Table E-4
Tracking and Conical
Scan Commands
Table E-5
RF Board Commands