TracVision 6 Technical Manual
Configure Longitude of a User-configurable Satellite
Function: configures one of the user-configurable satellites
with the longitude provided
Command: SATCONFIG,USERX,YYY,Z,D,L
Response: If valid, echoes the input data
If invalid, returns error message
Where: X = 1 or 2
YYY = longitude (0-180)
Z = E (East) or W (West)
D = decoding type (0 = test, 1 = DSS-A,
2 = DSS-B, 3 = DVB)
L = LNB polarization (C = circular, L = linear)
Set Saved Satellite Position
Function: sets saved satellite position
Command: GOTO,AZXXXX,ELYYY
Response: SAVED SAT POS: AZ = XXXX, EL = YYY
Where: XXXX = azimuth (0000 - 3599)
YYY = elevation (100 - 850)
E.7 Debug Commands
Enter Debug Mode
Function: enters Debug mode
Command: DEBUGON
Response: echoes the command, system enters Debug mode
Limit Switch Test
Function: performs a limit switch test
Command: =LSTEST
Response: Limit Switch Status: PASS
Set/Report Offset Angles
Function: reports or sets system offset angles
Command: OFFSETS
OFFSETS,XXXXX,YYYY
Response: Offsets = XXXXX.X YYYYY.Y
Where: X = azimuth offset (-1800 - 1800)
Y = elevation offset (-450 - 450)
Table E-7