LG Electronics 26-3DCH-UA CRT Television User Manual


 
PAGE 37
206-4071-D
011 - KEY DEFEAT (Keyboard Defeat)
If set to 1, key defeat prevents the end user from accessing the on-
screen menus with the TV front panel—MENU, SELECT, and Left / Right
arrow keys do not function. If set to 0, those keys do function. NOTE:
The menus can always be accessed by pressing MENU on the remote.
012 - IR BANKS EN (IR Banks Enable)
For direct access to a particular Channel Bank. When enabled, installer
can access a channel bank by inputting the IR code for the bank.
013 - SCAN MODE (Functional after 2-5-5+Menu setup transfer)
Allows variation in setting the TV On/Off with Channel UP/DOWN. You
may opt for TV channels only; TV channels + Off/ON; with these set-
tings for Scan Mode:
SCAN MODE Characteristics
0 Channel up/down keys change channels only.
1 Channel down below the lowest channel
(or channel up higher than the highest) and TV
turns off.
014 - STRT CH IN SM
(Start Channel in Scan Mode) If set to 1, installs TV On/Off event
below the start channel at TV turn On. If set to 1, the user can select
channels with either Channel Up/Down or by direct keypad entry. If
set to 0, only those channels that are entered for scanning can be
selected.
015 - SLEEP TIMER
If set to 1, the SLEEP TIMER feature may be used. If set to 0, the
Sleep Timer is not available.
016 - EN TIMER (Enable On/Off Timers)
If set to 1, Timer function is available to end user and enabled contin-
uously. Set to 0 to disable On/Off Timers. (Clock must be set in order
to use Timers.)
017 - ALARM *
Gives the installer the option of making the Alarm function
available to the end user. If set to 1, Alarm function is avail-
able to end user. Set to 0 to disable the Alarm function.
NOTE: Clock must be set before the Alarm function will work.
020 - FEATURE LEVEL
Installer should leave item 20 FEATURE LEVEL set to 1 (default).
Default set to ZEN 1 for Zenith IR codes remote control operation. Set
O, P LBL for Zenith Private Label IR remote control operation. Warning:
Do not set to “0” or remote will not control TV.
021 - V-CHIP (Parental Control)
Set to 1 to activate V-Chip (Parental Control); have it available to end
user to filter and control or otherwise restrict programming content
that can appear. Set to 0 to turn V-Chip feature Off, not available to
end user; no programming restrictions can be set.
* Only affects Function Menu if enabled by some PPV providers.
022 - MAX BLK HRS (Maximum Block Hours)
Sets hours from 0 to 99 for the maximum V-Chip (Parental Control)
block hours. Default setting is for 12 blocking hours.
023 - CAPTION LOCK
Set to 1 to restore previous caption On/Off state after turn Off. If set
to 0, captions are always Off at turn On.
025 - FUNCTION PRE (Function Preview)
Set to 0 to suppress CHANNEL PREVIEW from the FUNCTION menu with
some Pay-Per-View systems.
027 - HOSPITAL MODE
The default is 2 (which favors most hospitals). With this setting two
things are affected: Channel Banks 1, 2 and 3 are accessible, while
Bank 4 can be made inactive by removing all the channels from
Channel Bank 4. Then, if Channel Bank 4 is selected when the TV is
turned on, the TV screen will show “Inactive TV”. The Channel Bank 4
setup allows the hospital to present TV viewing options to the patient.
The patient can select programming options available in either Bank 1,
2 or 3. Channel Banks are available in all hospital modes 1 an 2.
• The IR code that will control the TV depends on Item 20-I Feature
Level setting.
Hosp. Mode = 0 Hospital Mode disabled.
Hosp. Mode = 1 Zenith P.L. IR Code (Bed 1)
Hosp. Mode = 2 Zenith IR Code (Bed 2)
028 - CH. OVERIDE (Channel Override)
If set to 1, the user can select channels with either Channel Up/Down
or by direct number keypad entry. If set to 0, only those channels that
are active in the TVs memory can be selected.
029 - OLD OCV (On Command Video
TM
)
Set to 1 for operation with systems from On Command Corporation.
030 - ACK MASK
M.P.I. Communication Parameter. Leave at default setting unless
changed by Pay-Per-View provider. When set to 1, changes M.P.I. for
some OCV boxes.
031 - POLL RATE
M.P.I. Communication Parameter. Selects Poll Rate for M.P.I. Leave at
default setting unless changed by Pay-Per-View provider. Step size of
16 ms.
032 - TIMING PULSE
M.P.I. Communication Parameter. Leave at default setting unless
changed by Pay-Per-View provider. Sets baud rate. Step size of 4.3 uS.
034 - CAMPORT EN. (Camera Port Enable)
Set to 1 to enable Video 2 input on display panel. If set to 0, Video 2
input on display panel is not functional.
NOTE: S-Video overrides Video jack.
Installer Menu