PDxx01 RS-232C Control Specification Page: 16 / 49
Document Version [1.0]
Company Restricted
5-19. TREBLE Gain Data
Function
The external control equipment changes the TREBLE gain data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA0 CKS
DATA00: USER PICTURE Gain Flag 05H
DATA01: TREBLE Gain Flag 04H
DATA02: TREBLE Gain F3H: -13
:
FFH: -01
00H: 0
01H: +01
:
0DH: +13
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag 05H
DATA01: TREBLE Gain Flag 04H
5-20. BALANCE Gain Data
Function
The external control equipment changes the BALANCE gain data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00: USER PICTURE Gain Flag 05H
DATA01: BALANCE Gain Flag 02H
DATA02: BALANCE Gain EAH: -22
:
FFH: -01
00H: 0
01H: +01
:
16H: +22
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag 05H
DATA01: BALANCE Gain Flag 02H