5-76. REMOTE CODE SETTING
Function
Remotecontroler codes are set.
Transmission Data
DFH 80H 60H 2BH 01H DATA00 CKS
DATA00 00H: ALL
01H: CODE1
02H: CODE2
03H: CODE3
04H: CODE4
ACK
7FH 60H 80H 2BH 01H DATA00 CKS
DATA00 00H: ALL
01H: CODE1
02H: CODE2
03H: CODE3
04H: CODE4
5-77. VOLUME Gain Data REQUEST
Function
The external control equipment inquires the volume gain for Plasma diaplay.
Transmission Data
1FH 80H 60H 0EH 00H CKS
ACK
DFH 60H 80H 0EH 01H DATA00 CKS
DATA00: VOLUME Gain : 00H~2AH
(00H: 0、0FH:15、10H:16、1FH、31・・・2AH:42)
: FFH: MUTE
5-78. UNDER SCAN SETTING
Function
Under scan are set up.
Transmission Data
DFH 80H 60H 22H 01H DATA00 CKS
DATA00: 00H OFF
01H ON
ACK
7FH 60H 80H 22H 01H DATA00 CKS
DATA00: 00H OFF
01H ON