Marantz PDxx01 Flat Panel Television User Manual


 
PDxx01 RS-232C Control Specification Page: 8 / 49
Document Version [1.0]
Company Restricted
5. Command
5-1. Power ON
Function
The external control equipment switches on the power of the plasma monitor.
Transmission Data
9FH 80H 60H 4EH 00H CKS
ACK
The plasma monitor returns the following ACK when the power is switched on.
3FH 60H 80H 4EH 00H CKS
5-2. Power OFF
Function
The external control equipment switches off the power of the plasma monitor.
Transmission Data
9FH 80H 60H 4FH 00H CKS
ACK
The plasma monitor returns the following ACK when the power is switched off.
3FH 60H 80H 4FH 00H CKS
5-3. Input Switch Change
Function
The external control equipment switches the input of the plasma monitor.
Transmission Data
DFH 80H 60H 47H 01H DATA00 CKS
DATA00 : Input Select 01H : Video1
02H : Video2
05H : DVD/HD1
06H : DVD/HD2
07H : PC/RGB
0EH : DVD/HD3(HDMI)
1AH : DVD/HD4(HDMI)
ACK
The plasma monitor returns the following ACK when the input is switched.
3FH 60H 80H 47H 00H CKS
NOTE: Do not set the Power ON or Power OFF command continuously.
NOTE: Do not set the Power ON or Power OFF command continuously.