PDxx01 RS-232C Control Specification Page: 44 / 49
Document Version [1.0]
Company Restricted
ACK
3FH 60H 80H 2DH 00H CKS
NOTE) Please select the memory you like to write by “68.PICTURE MEMORY Select” before setting “PICTURE
MEMORY NOTE WRITE”
5-68. SET UP LEVEL SELECT
Function
External control apparatus selects the Set up level function of a plasma monitor.
Transmission Data
DFH 80H 60H 35H 01H DATA00 CKS
DATA00 01H: 0%
02H: 3.75%
03H: 7.5%
ACK
7FH 60H 80H 35H 01H DATA00 CKS
DATA00 01H: 0%
02H: 3.75%
03H: 7.5%
5-69. BACK GROUND SELECT
Function
External control apparatus selects the Back ground function of a plasma monitor.
Transmission Data
DFH 80H 60H 36H 01H DATA00 CKS
DATA00 01H: Black
02H: Gray
ACK
7FH 60H 80H 36H 01H DATA00 CKS
DATA00 01H: Black
02H: Gray
Corresponding
character
A B C D E F G H I J
Received data (H) 10 11 12 13 14 15 16 17 18 19
Corresponding
character
K L M N O P Q R S T
Received data (H) 1A 1B 1C 1D 1E 1F 20 21 22 23
Corresponding
character
U V W X Y Z
Received data (H) 24 25 26 27 28 29