Marantz PDxx01 Flat Panel Television User Manual


 
PDxx01 RS-232C Control Specification Page: 36 / 49
Document Version [1.0]
Company Restricted
5-51. OSM ORBITER
Function
In order to decrease printing of a screen by OSM display, whenever it displays OSM, shift operation of the OSM is carried out.
Transmission Data
DFH 80H 60H 5FH 01H DATA00 CKS
DATA00 01H: ORBITER ON
02H: ORBITER OFF
ACK
7FH 60H 80H 5FH 01H DATA00 CKS
DATA00 01H: ORBITER ON
02H: ORBITER OFF
5-52. Input Skip
Function
In a monitor's key "an input change", when there is no signal, it flies and shifts to the following channel.
Transmission Data
DFH 80H 60H 61H 01H DATA00 CKS
DATA00 01H: ON
02H: OFF
ACK
7FH 60H 80H 61H 01H DATA00 CKS
DATA00 01H: ON
02H: OFF
5-53. SERIAL No. Request
Function
External control apparatus read
the serial number of the set recorded by EEPROM of a plasma display.
Transmission Data
1FH 80H 60H 15H 00H CKS
ACK
7FH 60H 80H 15H 0CH DATA00 to DATA11 CKS
Even DATA00-DATA11 is set up as follows.
Setting value 00H-09H : 0 - 9
96H : Blank
10H-29H : A-Z of Alphabet