NEC 120Mf Home Theater Server User Manual


 
4-5 Troubleshooting
On-screen error message Description Cause Action
0B94
IPMB signal lines do
not respond.
An SMC (Sattelite
Management
Controller) error
0B95
BMC FRU device
failure.
An error of the SROM
that stores the chassis
information
0B96
BMC SDR Repository
failure.
The access error to
FMEM sector in which
SDR information was
stored
0B97
BMC SEL device
failure.
A BMC device (chip)
failure
0B98 BMC RAM test error. BMC RAM error
0B99
BMC Fatal hardware
error.
BMC error
0B9A
Management
controller not
responding
BMC error
0B9B
Private I2C bus not
responding.
It-less answers from
private I2 C bus
0B9C
BMC internal
exception
BMC error
0B9D
BMC A/D timeout
error.
BMC error
0B9E
SDR repository
corrupt.
The error of BMC or
the data of SEL is
destroyed.
0B9F SEL corrupt.
The error of BMC or
the data of SEL is
destroyed.
BMC failed 1. Turn off AC and re-start
2. Replace Motherboard
0BB0
SMBIOS - SROM
data read error.
Incorrect SROM data
read
0BB1
SMBIOS - SROM
data checksum bad.
Incorrect SROM data
checksum
Turn off AC and
replace CPU#1
1. Turn off AC and re-start
2. Replace boards
0BC0
POST detected startup
failure of 1st
Processor.
Processor 1 error
Turn off AC and replace
CPU#1
0BC1
POST detected startup
failure of 2nd
Processor.
Processor 2 error
Turn off AC and replace
CPU#2
0BD0
1st SMBus device
address not
acknowledged.
A device-less answers
to 1st SMBus access.
0BD1
1st SMBus device
Error detected.
The error was detected
to 1st SMBus access
0BD2 1st SMBus timeout.
The timeout occurred to
1st SMBus access.
SMBus Access error
1. Turn off AC and re-start
2. Replace boards
3. Replace internal cables