NEC LCD5710 Flat Panel Television User Manual


 
English-28
Provides information on the status of the COOLING FAN,
BRIGHTNESS and TEMPERATURE.
COOLING FAN runs when internal temperature of the
monitor is over a specified limit.
BRIGHTNESS is decreased when internal temperature
of the monitor is over specified limit while the cooling fan
is in use. In this case, a warning is displayed on the
screen.
Adjusts the delay time between “standby” to “power on”
mode.
“POWER ON DELAY” time is selectable between
0 and 50 sec.
Adjusts the current date and time for internal clock.
You should set this function when you use “SCHEDULE”.
Programs the monitor’s working
schedule.
Schedules the power on and
power off with hour and day of
the week. Also sets the input port.
Select “EXIT” to set schedule.
(see “NOTE 3” on page 29 for
further information).
Selecting ADVANCED OPTION reset allows you to reset
all OSM settings from ADVANCED OPTION settings,
except for DATE & TIME, and SCHEDULE.
Select “YES” and press “SET” button to restore the
factory preset data.
Press “EXIT” button to cancel and then return the
previous menu.
ADVANCED OPTION
MONITOR ID
IR CONTROL
TILE MATRIX
HEAT STATUS
POWER ON DELAY
DATE & TIME
SCHEDULE
ADVANCED OPTION RESET
:SEL
SET
:NEXT :RETURN
MENU
:EXIT MENU
EXIT
:RETURN:SET
MENU
:EXIT MENU
DATE & TIME
YEAR
MONTH
DAY
TIME
DAYLIGHT SAVING YES / NO
CURRENT DATE TIME
JAN. 01. 2004 00 : 00 : 00
2004
JANUARY
01
00 : 00
SET
+ -: ADJ
EXIT
NOTE 1: IMAGE PERSISTENCE
Please be aware that LCD Technology may experience a phenomenon known as Image Persistence. Image Persistence occurs when a
residual or “ghost” image of a previous image remains visible on the screen. Unlike CRT monitors, LCD monitors’ image persistence is not
permanent, but constant images being displayed for a long period of time should be avoided.
To alleviate image persistence, turn off the monitor for as long as the previous image was displayed. For example, if an image was on the
monitor for one hour and a residual image remains, the monitor should be turned off for one hour to erase the image.
As with all personal display devices, NEC DISPLAY SOLUTIONS recommends displaying moving images and using a moving screen saver
at regular intervals whenever the screen is idle or turning off the monitor when not in use.
Please set “SCREEN SAVER”, “DATE &TIME” and “SCHEDULE” functions to further reduce the risk of Image persistence.
For long life use of Public Display
< Image Sticking of LCD Panel >
When LCD panel is operated continuously for long hours, a trace amount of electric charge remains near the electrode inside LCD, and a
residual or “ghost” image of previous image may be observed. This is called Image Persistence and is not permanent.
When a fixed image is displayed for a long period, ionic impurities inside the LCD accumulate along the displayed image. This is called
“Image Sticking” and is permanent.
< Recommendations >
For preventing the fast transition to Image Sticking, and for longer life usage of LCD, the following are recommended:
1. Fixed image should not be displayed for long period. Fixed images should be cycled in short intervals.
2. When not in use, do one of the following: turn off the monitor, use the Power Management Function to enter power save mode, or use
Schedule Function to turn off the monitor.
HEAT STATUS
DATE & TIME
SCHEDULE
ADVANCED OPTION
MONITOR ID
IR CONTROL
TILE MATRIX
HEAT STATUS
POWER ON DELAY
DATE & TIME
SCHEDULE
ADVANCED OPTION RESET
:SEL
SET
:NEXT :RETURN
MENU
:EXIT MENU
EXIT
ADVANCED OPTION RESET
:RETURN
MENU
:EXIT MENU
NO
YES
:SEL
EXIT
ADVANCED OPTION
MONITOR ID
IR CONTROL
TILE MATRIX
HEAT STATUS
POWER ON DELAY
DATE & TIME
SCHEDULE
ADVANCED OPTION RESET
:SEL
SET
:NEXT :RETURN
MENU
:EXIT MENU
EXIT
:RETURN
MENU
:EXIT MENU
POWER ON DELAY
3 SEC.
+ -: ADJ
EXIT
ADVANCED
OPTION RESET
ADVANCED OPTION
MONITOR ID
IR CONTROL
TILE MATRIX
HEAT STATUS
POWER ON DELAY
DATE & TIME
SCHEDULE
ADVANCED OPTION RESET
:SEL
SET
:NEXT :RETURN
MENU
:EXIT MENU
EXIT
EXIT
ADVANCED OPTION
MONITOR ID
IR CONTROL
TILE MATRIX
HEAT STATUS
POWER ON DELAY
DATE & TIME
SCHEDULE
ADVANCED OPTION RESET
:SEL
SET
:NEXT :RETURN
MENU
:EXIT MENU
EXIT
EXIT
:RETURN
MENU
:EXIT MENU
HEAT STATUS
STATUS
COOLING FAN1 ON
COOLING FAN2 ON
BRIGHTNESS NORMAL
TEMPERATURE
SENSOR 1 0.0 C / 32.0 F
SENSOR 1 0.0 C / 32.0 F
POWER ON DELAY