NEC LCD5710 Flat Panel Television User Manual


 
English-35
English
Mounting on Wall or Ceiling
DO NOT mount the monitor yourself. Please ask dealer.
For proper installation it is strongly recommended you use a trained, qualified technician.
Please inspect the location where the unit is to be mounted. Not all walls or ceilings are capable of supporting the weight of
the unit.
Product warranty does not cover damage caused by improper installation, remodeling, or natural disasters. Failure to follow
these recommendations could result in voiding the warranty.
To insure safe installation, use two or more brackets to mount the unit to at least two points on the installation location.
Please note the following when mounting on wall or ceiling
When using mounting accessories other than NEC compliant and approved, they must
comply with the VESA-compatible (FDMIv1) mounting method.
NEC strongly recommends using screws M8 size (15mm + bracket). If using screws longer
than 15mm, check the depth of the hole. (Recommended Fasten Force: 1125-1375N•cm)
NEC recommends using mounting interfaces that comply with UL1678 standard in
North America.
Mounting on wall or ceiling is the customer’s responsibility.
Prior to mounting, please inspect the installation location to insure that the location is
strong enough to support the mounted unit and that the unit will be safe from harm.
DO NOT block ventilated openings by mounting accessories or other items too close.
Refer to the manual included with the mounting equipment for detailed instructions.
Orientation
When using the display in the portrait position, the monitor should be rotated clockwise so that
the left side is moved to the top and the LED indicator light is on the bottom. This will allow for
proper ventilation and will extend the lifetime of the monitor. Improper ventilation may shorten
the lifetime of the monitor.
Mounting location
The ceiling and wall must be strong enough to support the monitor and mounting accessories.
DO NOT install in locations where a door or gate can hit the unit. Do not install in areas with lots of vibrations and dust.
DO NOT install near where the main power supply enters into the building. Doing so may cause fire and the electric shock.
Do not place where people can easily grab and hang onto the unit or mounting apparatus.
When mounting in a recessed area, as in a wall, leave at least 4 inches (10cm) of space between the monitor and the wall
for ventilation.
Allow adequate ventilation or air-conditioning around the monitor, so that heat can properly dissipate away from the unit
and mounting apparatus.
Mounting on ceiling
Ensure that the ceiling is constructed strong enough to support the weight of the unit and mounting apparatus over time
against earthquakes, unexpected vibration and other external forces.
Be sure that the unit is mounted to a solid structure within the ceiling such as a support beam. Secure the monitor using
the bolt, spring lock washer, washer and nut.
DO NOT mount to areas that have no supporting internal structure. Do not use wood screws or anchor screws for
mounting. DO NOT mount the unit to the baseboard or to hanging fixtures.
Maintenance
Periodically check for loose screws, gaps, distortions or other abnormalities. If an abnormality is detected please refer to
service person.
Over time, the mounting location may become weaker. Please check regularly.
Unit
Mounting
Bracket
Screw
15mm
Thickness
of Bracket
Screw length should equal
depth of hole (15mm) + the