Quick Programming Guide
(See Page 9)
ALARMS
The ExSite EHXM system has seven alarm inputs, which can be programmed as high, medium or low
priority. When an alarm is received, an input signal to the unit triggers the user-defined action (go to
preset, run pattern, etc.) programmed for the alarm.
There are three global alarm settings:
RESUME This mode lets the system resume its previous camera settings after all
alarms are cleared.
SEQUENCE This is the time the system will perform an alarm activity when more than one
alarm of the same priority occurs at the same time.
RESET DELAY This is the amount of time the system considers the alarm to be active after it
has physically cleared.
Use the following steps to program alarm settings.
1. Use the joystick to position the cursor beside ALARM SETTINGS. Press Iris Open.
2. Select the alarm number:
a. Use the joystick to position the cursor beside ALARM NUMBER.
b. Press Iris Open. The cursor moves to the right.
c. Move the joystick up or down to view selections. Press Iris Open to enter selection.
3. Select the alarm priority:
a. Use the joystick to position the cursor beside ALARM PRIORITY.
b. Press Iris Open. The cursor moves to the right.
c. Move the joystick up or down to view the available selections. Available settings include
HIGH, MEDIUM, and LOW (default). If multiple alarms with different priorities are active
at the same time, the dome will only go to the alarms with the highest priority.
d. Press Iris Open to enter selection.
NOTES:
HIGH alarm action takes highest priority and will override manual pan, tilt, and zoom
control.
MEDIUM/LOW alarm action will not occur if an alarm occurs during manual pan, tilt, and
zoom control.
4. Set the alarm action:
a. Use the joystick to position the cursor beside ALARM ACTION.
b. Press Iris Open. The cursor moves to the right.
c. Move the joystick up or down to view the available selections. The following are the
settings for alarm action:
NONE No action when alarm is triggered.
PRESET The system goes to the preset that is the same as the alarm
number. Preset 1 will go to Alarm 1.
PATTERN 1 The system runs pattern 1 when alarm is triggered.
PATTERN 2 The system runs pattern 2 when alarm is triggered.
PATTERN 3 The system runs pattern 3 when alarm is triggered.
PATTERN 4 The system runs pattern 4 when alarm is triggered.
d. Press Iris Open to enter selection.
EXIT
LANGUAGE ENGLISH
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<UNIT SETTINGS>
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
PELCO EXSITE EHXM
<CAMERA>
<OTHER>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<WINDOW BLANKING>
<ALARMS>
<WIPER>
<AUX>
<CLEAR>
<PASSWORD>
BACK
EXIT
UNIT SETTINGS
RESUME OFF
SEQUENCE (SECS) 5
RESET DELAY (SECS)
<ALARM SETTINGS>
BACK
EXIT
ALARMS
ALARM NUMBER 1
ALARM PRIORITY LOW
ALARM ACTION NONE
ACTIVATE AUX NO
ALARM CONTACT OFF
BACK
EXIT
ALARM SETTINGS