Pelco DX3100 DVR User Manual


 
10 C695M-B (11/03)
ALARM WIRING
Up to four alarm inputs can be wired to the DX3100. You can also connect up to two external devices to the unit. When an alarm input is
triggered, the unit begins alarm recording. It can also activate the external devices.
Use Figure 5 as a guide for wiring the alarm inputs and relay outputs.
Figure 5. Alarm Wiring Example
WARNING: The alarm relay output provides a maximum load of 1 A at 24 VDC. Therefore, it is recommended that you install a
fuse with your external circuit to protect the DX3100.
NETWORK CONNECTION
The DX3100 can be connected to other network equipment as part of a LAN (local area network). Contact your network administrator to
set up your connections properly, assign static IP addresses, and so on.
NOTE: The product’s network connection should be professionally integrated into existing on-site network configurations, where
possible. The connecting cable should meet or exceed Cat5 cable specifications.
LOAD: WARNING LIGHT
AUTO DIALER
EMERGENCY SIREN
WIRING
PANEL
IN OUT ALARM
G123 4G 1 2
EXTERNAL FUSE