1-12 Specifications
Table 1-1 Optical Module Characteristics (Cont.)
Module Name Protocols
Supported
Fiber Type
(Wavelength)
Connector
Type
Typical
Distance
Dynamic
Range
Optical
Power
(Typical)
Sensitivity
SM/FC/13LH***
(LASER)
TAXI, FDDI,
Fast Ethernet
STS-3c/STM-1,
STS-1
9/125
(1300 nm)
FC-PC 60 Km /
37.2 mile
33 dB -2 dBm -34 dBm
SM/FC/15LH***
(LASER)
TAXI, FDDI,
Fast Ethernet
STS-3c/STM-1,
STS-1
9/125
(1550 nm)
FC-PC 110 Km /
68.2 mile
33 dB -2 dBm -34 dBm
SM/SC/13L**
(LASER)
TAXI, FDDI,
Fast Ethernet,
STS-3c/STM-1,
STS-1
9/125
(1300 nm)
SC 40 Km /
24.8 mile
30 dB -12 dBm -31 dBm
SM/ST/13** TAXI, FDDI,
Fast Ethernet,
STS-3c/STM-1,
STS-1
9/125
(1300 nm)
ST 25 Km /
15.5 mile
30 dB -15 dBm -31 dBm
SM/ST/13L**
(LASER)
TAXI, FDDI,
Fast Ethernet,
STS-3c/STM-1,
STS-1
9/125
(1300 nm)
ST 40 Km /
24.8 mile
30 dB -12 dBm -31 dBm
SM/ST/13LH***
(LASER)
TAXI, FDDI,
Fast Ethernet,
STS-3c/STM-1,
STS-1
9/125
(1300 nm)
ST 60 Km /
37.2 mile
33 dB -2 dBm -34 dBm
SM/ST/15L**
(LASER)
TAXI, FDDI,
Fast Ethernet,
STS-3c/STM-1,
STS-1
9/125
(1500 nm)
ST 50 Km /
31 mile
30 dB -12 dBm -31 dBm
SM/ST/15LH***
(LASER)
TAXI, FDDI,
Fast Ethernet,
STS-3c/STM-1,
STS-1
9/125
(1550 nm)
ST 110 Km /
68.2 mile
33 dB -2 dBm -34 dBm
* Data Rates are switch-selectable from the front panel
** Transparent only
*** Retimed only
Note
Typical distances based on attenuation of 0.4 dB/Km for 1300 nm modules
and 0.25 dB/Km for 1550 nm modules