RAD Data comm AMC-101 TV Converter Box User Manual


 
AMC-101 Installation & Operation Manual Chapter 2 - Installation & Setup
AMC-101 Modules 2-35
10BT/B Module
AMC-B
10BT
TX
RX
LINK
COLL
Figure 2-36 10BT/B Module Front Panel
Connector: Shielded RJ-45
Used with: UTP Cat 5
Protocols supported: Ethernet (10Base-T): Half or Full Duplex
Timing mode: Retimed
Range: 100 m
Impedance:
100
Table 2-9 10BT/B Module Pinout
Pinout
Pin 1 Tx+
Pin 2 Tx-
Pin 3 Rx+
Pin 4
Pin 5
Pin 6 Rx-
Pin 7
Pin 8
Note
10BT/B modules (Half Duplex or Full Duplex) operate with Transparent
modules.